Home β€Ί Manufacturers β€Ί Siemens β€Ί 3VA5215-5ED31-0AA0
Siemens

Siemens 3VA5 UL Frame 250 Circuit Breaker | 3-Pole, 150A, 35kA

Siemens 3VA5 UL Frame 250, 3-Pole, 150A, 35kA Circuit Breaker

● In Stock 12-Mo Warranty Same-Day Dispatch Ships Worldwide πŸŽ– Veteran-Owned
In Stock β€” Ready to Ship
ManufacturerSiemens
Part number3VA5215-5ED31-0AA0
Part Number 3VA5215-5ED31-0AA0
Manufacturer Siemens
Series 3VA5 UL Frame 250
Poles 3
Get a price for 3VA5215-5ED31-0AA0
Response within 1 business hour

All orders subject to availability

πŸ›‘
12-month warranty
All units tested
⚑
Same-day dispatch
Order by 2pm CST
🌐
Worldwide delivery
US, EU, Asia, Middle East
πŸŽ–
Veteran-owned
CAGE: 9NK75
UL Listed 3-Pole Configuration TM210 Trip Unit with FTFM Permanently Set Overload Protection Moderate Breaking Capacity (35kA) Industrial Line Protection

The Siemens 3VA5215-5ED31-0AA0 is a 3-pole 3VA5 UL frame 250 circuit breaker designed for line protection in industrial settings. It offers a breaking capacity of 35 kA at 480 V. This model uses the TM210 trip unit with FTFM (adjustable thermal, fixed magnetic) protection, featuring permanently set overload protection (Ir=150 A) and short-circuit protection (Ii=10 x In). Rated for 150A, it is supplied without connection accessories.

This circuit breaker is suitable for main power distribution, feeder protection, and equipment protection in manufacturing facilities, commercial buildings, and infrastructure projects where moderate fault currents are expected.

Stanlo Automation, a veteran-owned distributor of surplus industrial automation parts, offers the Siemens 3VA5215-5ED31-0AA0. We provide reliable access to quality components, helping you maintain operational continuity with efficient service and competitive pricing.

Part Number3VA5215-5ED31-0AA0
ManufacturerSiemens
Series3VA5 UL Frame 250
Poles3
Current Rating (In)150 A
Breaking Capacity35 kA @ 480 V
Trip UnitTM210, FTFM
Overload Protection (Ir)150 A
Short-Circuit Protection (Ii)10 x In
ConnectionWithout
Main Power Distribution
Feeder Protection
Equipment Protection
Manufacturing Facilities
Commercial Buildings
Infrastructure Projects
UL 508A compliant industrial power distribution systems requiring 150A protection with 35kA interrupting capacity.
Siemens 3VA5 MCCB 3VA52155ED310AA0 Siemens 150A Protection Breaker
This circuit breaker can replace Siemens 3VA5 series breakers with a 150A rating and 35kA breaking capacity requirement. Verify compatibility with your system's protection needs.
Expert tip
The FTFM trip unit provides adjustable thermal overload protection and a fixed magnetic trip for short-circuit events.
1
Email confirmation
Immediate receipt acknowledgment sent to you
2
Account manager assigned
Confirms your part's spec and condition
3
Your quote delivered
Tailored to your specific requirements
What is the fixed short-circuit trip setting for the Siemens 3VA5215-5ED31-0AA0?
The Siemens 3VA5215-5ED31-0AA0 circuit breaker has a permanently set short-circuit protection (Ii) at 10 times the nominal current (10 x In). This provides a fixed instantaneous trip for significant fault currents.