Siemens 5SU1356-6KK10 RCBO - 10A, 6kA, Type A

Siemens RCBO 5SU1356-6KK10: 10A, 1P+N, 6kA, Type A, 30mA, B-Char.

● In Stock 12-Mo Warranty Same-Day Dispatch Ships Worldwide πŸŽ– Veteran-Owned
In Stock β€” Ready to Ship
ManufacturerSiemens
Part number5SU1356-6KK10
Breaking Capacity 6 kA
Poles 1P+N
RCD Type Type A
Rated Residual Current 30 mA
Get a price for 5SU1356-6KK10
Response within 1 business hour

All orders subject to availability

πŸ›‘
12-month warranty
All units tested
⚑
Same-day dispatch
Order by 2pm CST
🌐
Worldwide delivery
US, EU, Asia, Middle East
πŸŽ–
Veteran-owned
CAGE: 9NK75
Combined overcurrent and residual current protection 6 kA breaking capacity Type A RCD for AC and pulsating DC detection B-characteristic tripping for sensitive loads Compact 1P+N design

The Siemens 5SU1356-6KK10 is a Residual Current Breaker with Overcurrent protection (RCBO) featuring a 6 kA breaking capacity. This 1-pole plus neutral device is designed with Type A RCD sensitivity, capable of detecting AC and pulsating DC residual currents, and a 30 mA rated residual current. It utilizes a B-characteristic tripping curve, suitable for circuits with low inrush currents, and has a nominal current (In) of 10 A at 230 V AC.

This RCBO is ideal for applications requiring sensitive residual current detection and overcurrent protection, particularly in residential settings or for sensitive electronic equipment. The B-characteristic offers enhanced protection against earth faults by tripping at lower currents for short-duration overloads compared to C-characteristics.

Stanlo Automation, a veteran-owned surplus parts distributor, ensures availability of critical components like the Siemens 5SU1356-6KK10. We are dedicated to supporting industrial automation by providing quality surplus parts that help maintain operational continuity.

Breaking Capacity6 kA
Poles1P+N
RCD TypeType A
Rated Residual Current30 mA
Tripping CharacteristicB
Rated Current (In)10 A
Rated Voltage (Un AC)230 V
Residential circuits
Sensitive electronic equipment protection
Offices
Control circuits
Lighting installations
Standard 230V AC electrical distribution systems, particularly for sensitive applications
Siemens SENTRON RCBO B-Char 5SU1 356-6KK10 Siemens 10A Type A RCBO
Suitable as a direct replacement for individual RCD and MCB combinations or older RCBOs with similar ratings. Offers enhanced protection for sensitive circuits.
Expert tip
The B-characteristic is ideal for protecting circuits with minimal inductive or capacitive components, providing rapid response to fault conditions.
1
Email confirmation
Immediate receipt acknowledgment sent to you
2
Account manager assigned
Confirms your part's spec and condition
3
Your quote delivered
Tailored to your specific requirements
What is the main difference between B-Char and C-Char tripping curves on RCBOs?
The B-characteristic trips at 3-5 times the rated current, making it more sensitive to overcurrents and suitable for sensitive loads. The C-characteristic trips at 5-10 times the rated current, designed to handle moderate inrush currents typical of lighting or socket circuits.